So, when it came to his own home design, Vent was on his radar. Part of Tom’s plan was a warm roof to improve energy efficiency, and the following case study explains how Vent products can be used to future proof a new build and mitigate dew point moisture.
A quick physics lesson.
It’s thanks to a natural phenomenon called night sky radiation. A process where surfaces lose heat to the atmosphere. When the night sky is clear and still, heat from objects outside radiates upwards, cooling surfaces to below air temperature.
When surfaces cool below dew point (the temperature at which air becomes saturated), moisture in the air condenses onto them, forming dew. That’s why the grass often appears wet in the morning, even if it hasn’t rained.
This Process Affects Iron Roofing.
In a typical home, roofing is laid directly on top of the underlay and screwed into the purlin. As the iron cools thanks to night sky radiation, the coolness of the iron transfers to the underlay sitting snugly below, dropping the underlays temperature below air temperature and causing condensation on the back of the underlay.
This condensation risks compliance of E2 3.5, which governs moisture transfer in buildings.
E2 mandates the need for moisture management, specifying materials and construction techniques that must keep water from penetrating the building envelope while allowing any trapped moisture to escape. Vent products are BRANZ certified to mitigate condensation and moisture issues as per the New Zealand building code.
What is a Warm Roof?
In this scenario a complete Vent passive ventilation system is not required. However, a key element of a successful warm roof is dew point separation. Without it, even warm roof iron roofs can be prone to moisture issues from nighttime condensation and Tom was concerned about this impacting his new build’s health and longevity.
Vent VB10 Mitigates Moisture for E2 3.5 Compliance
“With a dark-coloured roof, the ventilation is crucial to let built-up heat escape. The separation of the roofing and underlay is also very important. It’s a great product, and I’m glad to have it on our house,” says Tom.
VB10 strips are easy to install with a peel and stick adhesive backing eliminating the need for extra nails or glue.
Why Add VB10 to a Warm Roof?
“The vent strips were very easy to work with and install. The peel and stick feature made fixing the roofing through the vent strips to the purlins simple and effective,” says Tom.
More info on the VB10.
VB10 is recommended for skillion and trussed roofs.
The VB10 is a polypropylene ventilation and drainage batten compatible with steel and timber framing and suitable for residential or commercial projects.
It’s easy to install with a simple peel-off adhesive backing, eliminating the need for nails or glue. Strong and durable, the VB10 has been tested to exceed foot traffic weight requirements on the roof.
Talk to us about installing VB10 for dew point protection.